Failures
Add new failure
Family
Status
Search
QF-2001
Family
DNA
Status
In Analysis
Work order number
WO-10458
Serial
SN-88421
Module number
MOD-17A
Reason
Electrical Failure (ELEC)
Inspector
Alex Carter
Date
2026-03-18
Detailed comment
Output rail drops below threshold during power-on validation.
Root cause
Cold solder joint found on the output regulation path.
QF-2002
Family
DNR
Status
Open
Work order number
WO-10463
Serial
SN-88477
Module number
MOD-22C
Reason
Mechanical Failure (MECH)
Inspector
Morgan Lee
Date
2026-03-20
Detailed comment
Internal support bracket is misaligned after final assembly torque step.
Root cause
Not added yet
QF-2003
Family
DNF
Status
Open
Work order number
WO-10479
Serial
SN-88502
Module number
MOD-31F
Reason
SMD Failure (SMD)
Inspector
Taylor Brooks
Date
2026-03-22
Detailed comment
One passive component shows tombstoning after reflow inspection.
Root cause